Spacer Bar Systems

Spacer bar systems support the external sheets in built up roofing and wall cladding. Galvanised steel bars and brackets create the cavity for insulation, with different bar lengths and bracket heights to suit the specified construction.

Bars & Brackets

Spacer bars provide the fixing face for the external roof or wall sheets. Brackets connect the bars to the supporting purlins or cladding rails, transferring loads from the outer sheets back to the structure.

In twin skin systems, the assembly maintains the space between the liner and external sheets for the specified insulation. The bar profile, bracket height and support arrangement are selected together to suit the roof or wall application.

Spacer System Options

Bar Lengths

Bar lengths include 1m, 2m and 3m, depending on the selected system. Choose lengths to suit the required runs, joint positions and installation layout.

Check the effective fitted length and connection detail when calculating quantities. Bracket spacing is established separately from the bar length, using the system’s load data and the supporting structure.

Bracket Heights

Bracket heights range from 60mm to 300mm, depending on the selected system. The required height is chosen alongside the insulation specification and the roof or wall build up.

Confirm how the bracket height is measured within the chosen system. The finished construction depth also depends on the liner profile, bar arrangement and external sheet. Allow for the required details at rooflights, eaves and other junctions.

Fixings & Accessories

Depending on the system, the assembly may include thermal isolator pads, bar connectors, stabilising brackets and specified fixings. Some connections and stability features are incorporated into the bar or bracket design.

Thermal pads help limit heat transfer at the bracket base. Joint details and any additional restraint must follow the selected system’s requirements.

Fixings are selected for the bracket connection, supporting material and design loads, with the correct drilling capacity and thread engagement for the application.

Specification & Compatibility

Use compatible bars, brackets, connections and fixings specified for the selected spacer system. Bracket centres and fixing arrangements must suit the supporting structure and design loads, using the system’s current load tables and installation guidance.

Thermal performance is assessed for the complete roof or wall, accounting for the insulation and heat transfer through the spacer assembly. Changes to bracket height, spacing or other components should be checked against the required structural and thermal performance.