Pipe Flashings
Pipe flashings seal around pipes and vents where they pass through roofing sheets. A flexible collar seals against the pipe, while a formable base follows the roof profile to complete the weather seal.
Standard & Retrofit Pipe Flashings
Standard pipe flashings slide over the end of the pipe and are positioned at roof level. They suit installations where the pipe is accessible from above and any fittings allow the flashing to pass over.
Retrofit flashings wrap around existing pipework where fittings or other obstructions prevent access from above. The split is secured using the product’s own closure system, allowing the flashing to be fitted without passing it over the pipe.
Pipe Flashing Options
Size & Roof Fit
Select the flashing using the pipe’s outside diameter where the collar will seal. This is different from the nominal pipe size or the opening through the roof. The selected product must also suit the roof pitch.
The base needs enough space to follow the sheet profile and form a continuous seal around its perimeter. Deep profiles or awkward positions may require a different base size or flashing design so water can drain freely around the penetration.
Materials & Temperature
EPDM is commonly used for general pipe and vent flashings. Silicone options provide higher temperature resistance where the application requires it. Material choice is separate from whether the flashing fits over the pipe or wraps around it.
Check the temperature of the outside pipe surface where it contacts the flashing, rather than the gases or liquids inside. Compare this with the selected product’s continuous operating limit and any permitted short periods at higher temperatures.
For flues, follow the flue manufacturer’s roof penetration detail and required clearances. The flashing provides a weather seal; its temperature rating does not establish the fire performance of the complete installation.
Fitting & Sealing
Follow the selected flashing’s instructions for trimming and fitting the collar. Prepare the roof surface, form the base to the sheet profile and use the specified compatible sealant and fixings. Secure the base evenly without distorting the sheet or damaging the flashing.
Both the seal around the pipe and the seal beneath the base need to be complete. Fit any specified clamp or retrofit closure using the manufacturer’s method; sealant does not replace a required mechanical fastening.
During routine roof inspections, check for splits, lifting edges, loose fixings or damaged sealant, and keep the surrounding drainage paths clear.