Liner Sheets

Profiled steel liner sheets form the internal face of twin skin roof and wall systems. Options include non perforated sheets for standard linings and perforated sheets for acoustic constructions, with profiles, thicknesses and finishes selected to suit the building.

Roof & Wall Liners

Liner sheets are fixed to supporting purlins or cladding rails, with insulation, spacer systems and external weather sheets completing the twin skin construction. The exposed internal face provides a finished lining in warehouses, workshops and other industrial or commercial buildings.

Where a non perforated liner is used for air and vapour control, its laps, perimeter junctions and penetrations must be sealed to the system specification. Some constructions require a separate membrane, so the control arrangement should be confirmed with the selected roof or wall system.

Liner Options

Profiles & Thicknesses

Liner sheets are available in shallow and deeper trapezoidal profiles. Common steel thicknesses include 0.4mm and 0.7mm, depending on the manufacturer and profile. These figures describe the steel thickness rather than the depth of the ribs.

Select the profile and thickness using the manufacturer’s load/span data for the proposed support centres, loads and fixing arrangement. The liner must also suit the specified spacer system and bracket details.

Where access over the liner is required during installation, specify a system assessed for that purpose. A 0.7mm sheet alone does not establish that the installed liner is suitable to walk on.

Colours & Finishes

White polyester is a common internal liner finish, providing a bright surface that reflects daylight and artificial lighting. Other colours and specialist reflective finishes depend on the selected manufacturer and profile.

Choose the coating for the conditions inside the building. High humidity, livestock housing, chemical exposure or regular washdown may require a different finish from a standard internal polyester coating.

Specify the coating, colour reference and intended exposed face together. Where liners meet existing sheets or visible internal flashings, use a physical sample to check the proposed colour and finish.

Acoustic Liners

Perforated liner sheets allow sound to reach absorbent material behind the steel, helping reduce reflected sound and reverberation inside the building. Depending on the profile, perforations may be confined to the troughs or extend across the sheet.

The perforation pattern, acoustic backing and insulation must follow the specified construction. Sound absorption performance applies to the complete assembly, and reducing reverberation is different from limiting noise passing through the roof or wall.

Perforated liners do not provide a continuous air and vapour seal. Any required control layer must be incorporated separately in the position specified for the acoustic system.

Lengths & Cover Width

Sheet lengths: Liners are supplied to specified lengths within the selected manufacturer’s production limits. Coordinate lengths and any end laps with the supporting structure, openings and installation sequence. Handling requirements can limit practical sheet lengths, particularly with thinner liners.

Cover width: This is the installed width covered by each sheet after allowing for the side lap. Use the selected profile’s cover width when calculating quantities, rather than its overall width.

Replacement sheets: Match the profile shape, depth, cover width and side lap detail. Similar looking liners may not fit together correctly.


Use our Profile Identifier form (PDF) to record the liner profile, dimensions and side lap details. Include clear end view photographs taken safely.

Fixings & Accessories

Select fixings and accessories to suit the liner profile, supporting material and specified roof or wall construction.

For more information on liner joint sealing products, see our Cladding Tapes and Sealants guide (PDF).