Composite Panel Fixings

Composite panel fixings secure insulated roof and wall panels to light steel, heavy steel or timber supports. The screws shown below use an upper support thread to help support the panel’s outer sheet beneath the head and sealing washer.

Composite Panel
to Light Steel

Composite panel screws for light steel secure insulated roof and wall panels to cold rolled purlins and rails. Our standard screws have a 5.5mm coarse fixing thread and No. 2 drill point.

Select the screw for the actual steel thickness and the panel build up at the specified fixing position. The lower fixing thread must engage the supporting steel correctly.

Composite Panel to Heavy Steel

Composite panel screws for heavy steel secure insulated roof and wall panels to thicker steel supports, including hot rolled sections. Our standard screws have a 5.5mm fine fixing thread and extended No. 5 drill point.

Check the support thickness and steel grade against the selected screw’s application limits. Allow the specified projection beyond the steel so that the lower fixing thread engages the support correctly.

Composite Panel to Timber

Composite panel screws for timber secure insulated roof and wall panels to timber purlins and rails. Our standard screws have a 6.3mm coarse fixing thread and Type 17 gash point to assist entry into the timber.

Choose the length using the published panel range and the required full thread engagement in sound timber. The gash point and any plain shank are excluded from that engagement.

Fixing Options

Panel Range & Selection

Choose the screw using its published panel range, including any stated minimum and maximum. The lower fixing thread must reach and engage the support correctly; overall screw length alone does not establish suitability.

Check the full depth at the fixing position, including the panel profile and any specified packers, washers or load spreading components. Follow the product data’s definition of the range and its allowances. Core thickness alone may not represent the depth being fixed.

Our Fixing Length and Application Ranges guide (PDF) explains panel build up, thread position and the measurements needed for selection.

Heads & Washers

Head options include standard and painted hex heads, alongside integral moulded colour heads. Specify the required BS or RAL colour reference and confirm availability for the selected fixing.

Separate colour caps fit over compatible hex heads after installation. Check the cap against both the head and washer dimensions; it provides a coloured cover while the sealing washer beneath provides the seal.

Use the sealing washer and any profiled load spreading washer or spreader plate specified for the panel system. The complete arrangement must suit the panel profile, fixing position and required connection performance.

See Sealing Washers Explained (PDF) for guidance on washer selection and seating.

Coatings & Corrosion

Our imported composite panel screws are manufactured from carbon steel with a protective Ruspert coating. Select the fixing material and corrosion protection to meet the panel system’s requirements and the building’s exposure conditions.

Consider moisture, coastal salts and conditions inside the building, together with compatibility with the panel facings, supporting structure and any timber treatment. Head colour alone does not establish the corrosion performance of the complete fixing.

Our Coatings and Corrosion Guide (PDF) explains protective finishes, exposure considerations and salt spray test results.

Panel Compatibility & Installation

Follow the panel system’s fixing detail, including fixing positions, sealing washers and any load spreading components. Concealed wall-panel joints may require a different screw design or a specified spreader plate. Confirm compatibility with the joint detail before selecting the fixing.

Use a variable-speed screw gun with suitable depth control and the correct socket. Do not use an impact driver. Seat the sealing washer evenly without distorting the outer sheet or crushing the panel.

Our Fixing Selection and Installation Guide (PDF) covers installation and care. For explanations of connection test results, see Understanding Fixing Performance (PDF).